SIPTEC WALL, ROOF & FLOOR SIP PANELS:-

FIRE TESTING,  OSB/ PLASTERBOARD FACINGS

BRE    Structural Fire Test Partition Wall   BS 476 Part 22   Report No 211093

BTC    Structural Fire Test External Wall   BS 476 Part 21  Report No F53061F

BTC    Structural Fire Test Roof Panel       BS 476 Part 21  Report No 130601F  

 ACOUSTIC TESTING

            OSB/ PLASTERBOARD FACINGS

            BTC Acoustic Testing Partition Panel to BS – EN – ISO140-3   Report 13028A

  BTC Acoustic Testing Partition Panel to BS – EN – ISO140-3   Report 13029A

 STRUCTURAL TESTING : SIPTEC WALL AND ROOF PANEL WITH OSB FACINGS.

           UKAS Approved Laboratories Report No  SW153-03

           RACKING TESTS EN594:1995

 AXIAL COMPRESSIVE STRENGTH :-BS5268:part 2

 ECCENTRIC COMPRESSIVE STRENGTH :- BS 5268 Part 2

 UNIFORMLY DISTRIBUTED LOAD,  Roof & Floor Load  to BS 6399: Part 1

 POINT LOADING to Floor 6399: Part1

 HARD BODY IMPACT TESTS : BS EN 596:19964

 SOFT BODY IMPACT TESTS : BS EN  8200:19854

 UNIFORMLY DISTRIBUTED LATERAL LOAD (WIND LOAD) :BS 6399: Part 2

 SIPTEC DUPLEX TEST REPORT SW153.03B

 AXIAL COMPRESSIVE STRENGTH  BS 5268: Part 2

HIGH RISE HOTEL PANEL TESTING

 INFILL STRUCTURAL PANELS WITH WINDOW APERTURES

UDL DEFLECTION TESTS BS 6399 REPORT NO.

 AXIAL COMPRESSION TESTS ON 3.5 METER WALL PANEL WITH,  Alternative Load Path.

 B R E  UKAS Approved Laboratories.  

bullet

  RACKING TESTS TO EN594 150 MM SIPTEC WALL PANEL WITH CPB FACINGS

bullet

 AXIAL COMPRESSION TESTING BS5268: Part 2 150 MM  CPB FACINGS

 SURREY UNIVERSITY ENGINEERING LABS.

 RACKING TESTS :- BS EN 594 ON SIPTEC WALL PANELS 100 MM OSB FACINGS

All test data by UKAS accredited Labs.

Dimensions

Widths available, 300 — 1200 mm.

Std Wall Heights    2.4, 2.7, 3.0 mtr

Roofing Sips up to 4.8 mtr long

All sips are available in the following

Thickness, 

80, 100, 125, 150, 180, 225 mm

Facings std OSB3, OSBZ, CPB

Thickness std 11 mm & 15 mm

Available in OSB & CPB up to 40 mm.

Other facing materials Plastic, Steel,

Plywood, Aluminium, etc, on request.

———————————

Thermal Performance

Siptec SIPS PIR core

Conductivity λ0.022w/m°k (aged k)

U Value See tech Sheets

Fire Performance

BS476 part 21. 3mtr x 3mtr OSB panel plasterboard faced loaded to 35knm Passed 1 hour 10 mins +

When lined internally with 12.5 mm plasterboard the Siptec system will achieve. Class O, Building Regulations.

Construction Recommendations.

Internal walls use either 80 or 100 panel

With 12.5 mm plasterboard on each side

Acoustic value 40db

Fire resistance = ½ hour.

1 layer 12.5mm sound block &

1 layer 12.5 mm plasterboard

Acoustic value 46db

Fire resistance, 1 hour.

External Walls

The ultimate wall is Siphouse 225 with external brick skin; this combination creates a virtual zero energy loss walls. Low cost wall use the 100mm panel + external facing, more than meets building regs.

Loading Capacity Walls

100 mm  SIP (our weakest panel)

Axial BS5268

225 knm  Safety Factor 3 = 75 knm

Eccentric loading

122.82 knm Safety Factor 3 = 40.94 knm

Siphouse Wall panel loading

Connected by restrained stud method

477 knm safety factor 1.6 = 298 knm

Racking BS 5268

Mean Load, 0 KN R=2290/mm²

Mean Load,  5 kn R=2783/mm²

Concentrated Load

On centre of panel = 7.1 KN

 

Mid span on Joint   = 7.9 KN

Hard Impact BS EN 596,   passed

Soft Impact                      passed

Lateral UDL    upto 23.5 knm²

Test abandoned after test rig bending

Siptec Roofing SIPS

 

150 mm Panel Span 3 meter

30 mm deflection Ĺ/200 @ 4.2knm

Loaded to 21kn/m² test rig bent

225 mm Panel Span 6 meter

30 mm deflection L/200 @ 3.26knm

Loaded to 21 kn/m² test rig bent

——————————–

Siptec Cladding Panels

Suitable for Steel & concrete framed multi story buildings. These Sips are also used for cladding or infill on Green Oak structures these Sips are produced in all thickness and sizes to meet clients specs.

Siptec have completed extensive UDL testing and can provide data on panel stiffness, deflection etc.

Ask for Panel Cladding Data Sheets

Roofs

All thicknesses of Siptec panels can be delivered with camlocks and are suitable for roofing any building

horizontal rule

Home | About Us | Site Map

       
Copyright Siptec all rights reserved 2000-2007